rp2/machine_timer: Fix printing of timer period.
Showing the period alway as microsecond quantities, since tick_hz is assumed as 1_000_000 if the period is given by freq=xxx. If the period is larger than 0xffffffff, the value is divided by 1000 and "000" is appended in the display. That works for periods up to about 50 days. Signed-off-by: robert-hh <robert@hammelrath.com>
This commit is contained in:
@@ -57,7 +57,12 @@ STATIC int64_t alarm_callback(alarm_id_t id, void *user_data) {
|
|||||||
STATIC void machine_timer_print(const mp_print_t *print, mp_obj_t self_in, mp_print_kind_t kind) {
|
STATIC void machine_timer_print(const mp_print_t *print, mp_obj_t self_in, mp_print_kind_t kind) {
|
||||||
machine_timer_obj_t *self = MP_OBJ_TO_PTR(self_in);
|
machine_timer_obj_t *self = MP_OBJ_TO_PTR(self_in);
|
||||||
qstr mode = self->mode == TIMER_MODE_ONE_SHOT ? MP_QSTR_ONE_SHOT : MP_QSTR_PERIODIC;
|
qstr mode = self->mode == TIMER_MODE_ONE_SHOT ? MP_QSTR_ONE_SHOT : MP_QSTR_PERIODIC;
|
||||||
mp_printf(print, "Timer(mode=%q, period=%u, tick_hz=1000000)", mode, self->delta_us);
|
mp_printf(print, "Timer(mode=%q, tick_hz=1000000, period=", mode);
|
||||||
|
if (self->delta_us <= 0xffffffff) {
|
||||||
|
mp_printf(print, "%u)", (uint32_t)self->delta_us);
|
||||||
|
} else {
|
||||||
|
mp_printf(print, "%u000)", (uint32_t)(self->delta_us / 1000));
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
STATIC mp_obj_t machine_timer_init_helper(machine_timer_obj_t *self, size_t n_args, const mp_obj_t *pos_args, mp_map_t *kw_args) {
|
STATIC mp_obj_t machine_timer_init_helper(machine_timer_obj_t *self, size_t n_args, const mp_obj_t *pos_args, mp_map_t *kw_args) {
|
||||||
|
|||||||
Reference in New Issue